Ga file wp 3241
WebGA WP 4232. Chase Wall - Wood Stud (Load-Bearing) Fire Rating: 2 hours: System STC: 53 System Thickness: 11.75 in. CAD/Revit & Acoustics. Revit PDF. Visit GA WP 4232 … WebGA-223-2024 Gypsum Panel Products, Types, Uses, Sizes, and Standards Summarizing the many different types of gypsum board used in the industry, this quick reference gives typical uses of, and the ASTM and CSA standards for, […] Read more GA-1000-2024 Identification of Gypsum Board
Ga file wp 3241
Did you know?
WebFire Rated Designs U375 and GA File # ASW 1004.1 Sound Test NOAL 20-0209 (STC 65) MOLD & MILDEW RESISTANCE American Gypsum o˜ers extra protection against mold and mildew with our M-Bloc or M-Glass Shaft Liner panels to protect the owner, builder and architect during construction. In independent laboratory tests per ASTM D3273, both … WebGA WP 3341 C Durasan laminated to 1/4" gypsum wallboard nailed to both sides 2 x 4 (38 mm x 89 mm) studs, spaced 16" o.c. (406 mm). 7 2 hr. FM WP-360 5/8" (15.9 mm) Fire …
WebGA File No. WP 1530 / 1545 Drawing. ... GA File No. WP 2961 Drawing. GA File No. WP 3241 Drawing. GA File No. WP 3605 Drawing. GA File No. WP 4135 / 4136 Drawing. … WebAug 28, 2024 · Fire Test Reference: GA WP 3725. Sound Test Reference: NGC-3056, NOAL 17-0842, 8-28-17, NOAL 17-0843, 8-28-17. Approved for Assembly: DensArmor Plus® Fireguard C® Products DensArmor Plus® Fireguard® Products DensElement® Barrier Sheathing DensGlass® Fireguard® Sheathing
WebMar 25, 2013 · GA File # WP 3241. STC - 50. Sound Test # TL-93-196. Resilient furring channels attached 24” o.c. horizontally to one side. of 2x4 wood studs 16” or 24” o.c. with … WebOct 27, 2014 · wood framed walls & partitionsstc 60 - 64 55 - 59 ga file no. wp 3010 wp 3110 wp 3810 wp 3812 wp 3820 wp 5510 wp 5520 wp 3240 wp 3241 wp 3242 wp 3243 wp 3244 wp 3245 wp 3260 wp 3910 wp 5530 wp 3330 wp 3340 wp 3341 wp 3343 wp 3360 wp 3370 wp 5512. 50 - 54. 55 - 59. 35 - 39. 45 - 49. 30 - 34. 35 - 39. 30 - 34. ga …
WebGA-FILE-NO-WP-8109. Title. GA-FILE-NO-WP-8109. Author. Powers. Created Date. 2/26/2007 11:39:53 AM.
WebOct 1, 2006 · Another sound reducing method is depicted in GA file WP 3242. This design uses resilient channels on one side of wood studs to create a spring-like, sound … speedy septic tank services chinle arizonaWebJun 23, 2011 · ga file no. wp 1204 wp 1206 wp 1240 wp 1290 wp 1296 wp 1714 wp 1716 wp 6130 wp 6135 wp 6152 wp 1311 wp 1330 wp 1340 wp1350 wp 1370 wp 1380 wp 1390 wp 1400 wp 1830 wp 1841 wp 1870 … speedy services bridgwaterWebga file no. wp 3825 proprietary interior wood framed stairwell walls interior wall assemblies 2 hour fire 55 to 59 stc sound w-2 non rated assembly interior wood framed plumbing wall w-b ul design no. v311 proprietary exterior thin brick cladding 1 hour rated w-1 non rated assembly interior cmu non load bearing interior wall assemblies w-a per ... speedy services hvoWeb1-hr - ga file # wp 3514 1/2" plywood shtg. 5/8" type "x" tile backing gyp. bd. stc: 35 - 39 note: when such panels are applied under the gypsum board or between layers of gypsum board the length of the fasteners specified for the attachment of the gypsum board applied over the wood structural panels shall be increased by not less than the ... speedy sense media thailandWebGA FILE NO. RC 2602 1-HR ROOF 1-HR R2 N/A N/A R-20 MIN POLYISO RIGID INSULATION STANDING SEAM METAL ROOF 11B: OMIT EXTERIOR GYPSUM SHEATHING ISSUE DATE Sinan Gumusoglu Architecture LLC 12564 SW Main Street Tigard, OR 97223 (971) 336 -8179 [email protected] PO Box 3026 Clackamas, … speedy services grangemouthWebCertainTeed Home speedy services haydockWebFM WP-755 C-T Studs or C-H Studs 24" o.c. (610 mm). 1" (25.4 mm) 2001003 GA WP 6905 Fire-Shield Shaftliner or 1" Fire-Shield Shaftliner XP,one layer of 5/8" (15.9 mm) Fire-Shield Gypsum Wallboard applied horizontally or vertically on side opposite shaftliner. Fire tested both sides. 1 1/2" (38.1 mm) mineral wool or glass fiber in cavity. 42 NGC ... speedy services nsc